logo Shrinathji Enterprises Slideshow

 

BUILDING WIRES
 
Superex FR
Unilay FR
Flamex FR-LSH
Firex HFFR

 

  SUPEREX FR
  Flame Retardant Cable - upto 1100V
Applications: Suitable for use in conduit and for fixed, protected installation.

Conductor: Many thin strands of Electrolytic Copper are fine - drawn simultaneously for uniformity of Resistance, Dimension, and Flexibility. The drawn strands are twisted in high precision machines which imparts circularity to the conductor.

Insulation: Specially formulated Lead free + Flame retardant PVC insulation is used. The FR (flame retardant) property retards the propagation of flame without compromising safety.

Insulation Conformity: IS 5831 Type A, FR.

Approvals: IS 694 marked, FIA/TAC approved - CM/L 7205255.

Marking: The cables are printed with generic marking “SUPEREX-FR”.

Colours: Red, Yellow, Blue, Black, Green, Grey.

Packing: 90 mtrs. coils packed in protective cartons. Project coils of 180 mtrs also available.

^ To Top

  UNILAY FR
  PVC Flame Retardant Cable - upto 1100V
- India's 1st Flame Retardant RoHS
- Compliant cable with Unilay Conductor
- No Loose contacts, No Broken ends
- No sparking & overheating

Applications: Suitable for use in conduit and for fixed, protected installation. Ideal for high density wiring.

Conductor: Thin strands of Electrolytic Copper are multi - drawn simultaneously for uniformity of Resistance, Dimension, and Flexibility. The drawn strands are uni-laid in high precision machines and compacted. A perfectly circular conductor is thus formed. This enables reduction in overall diameter for space saving in high density wiring. The strands do not get cut when stripping the insulation. The conductor offers perfect contact at pins, terminals and sockets. This eliminates spot heating and sparking.

Marking: The cables are printed with generic marking of “UNILAY-FR".

Colours: Red, Yellow, Blue, Black, Green, Green/Yellow, Grey.

Insulation: Specially formulated Lead free + Flame retardant PUCinsulation is used. The FR (Flame Retardant) property retards the propagation of flame, hence without compromising safety.

Insulation conformity: 155831 type A, FR.

Approvals: IS 694 marked, FIA/TAC approved - CM/L 7205255.

Packing: 90 mtrs. coils packed in protective cartons.

^ To Top

  FLAMEX FR-LSH
  Flame Retardant Low Smoke Low Halogen - upto 1100V
Applications: Suitable for use in conduit and for fixed protected installation particularly suitable for wiring in fire and explosion prone areas, chemical factories, densely wired areas, public buildings, schools, hospitals, commercial complexes, theatres, etc.

Conductor: Many thin strands of Electrolytic Copper are fine-drawn simultaneously for uniformity of Resistance, Dimension, and Flexibility. The drawn strands are twisted in high precision machines which imparts circularity to the conductor.

Insulation: Specially formulated grade of Flame Retardant Low Smoke Low Halogen compound to restrict the spread of flames in fire situation. The smoke emitted by the burning cable is considerably low compared to traditional cables. This ensures improved visibility for evacuation of trapped victims and facilitates fire fighting operation.

Insulation Conformity: IS 5831 Type A FR-LSH.

Approvals: IS 694 marked, FIA/TAC approved - CM/L 7205255.

Colours: Entire cable has White base and a double strip of Red, Yellow, Blue, Black, Green running along the length of the cable.

Packing: 90 mtrs. coils packed in protective cartons. Project coils of 180 mtrs also available.

Marking: The cables are printed with generic marking “FLAMEX-FR-LSH”.

^ To Top

  FIREX HFFR
  Halogen Free Flame Retardant Cable - upto 1100 V
- India's 1st Fire-safe Cable with HFFR insulation and UNILAY conductor
- Zero Halogen
- Does not catch flame, does not propagate fire
- Non-Toxic, Non-Corrosive.

Applications: Wiring in all installations where fire safety is of utmost importance. Schools, theaters, commercial complexes, apartments, high rise buildings, laboratories, etc.

Conductor: Thin strands of Electrolytic Copper are multi - drawn for uniformity of Resistance, Dimension and Flexibility. The drawn strands are uni-laid in high precision machines and compacted. Thus forming a perfectly circular conductor which enables reduction in overall diameter for space saving in high density wiring. The strands do not get cut when stripping the Insulation. The conductor offers perfect contact at pins, terminals and sockets. Thus eliminating spot heating and sparking.

Insulation: Specially formulated grade of Halogen Free Flame Retardant (HFFR) compound is used. The insulation does not burn readily. It does not melt and drip, smoke is negligible, transparent, non toxic. The victims trapped in fire do not suffocate and this facilitates fire fighting operations. Unlike PVC, the smoke emitted is non-corrosive.

Insulation conformity: IEC 60332-1 & 3, IEC 60754-1&2. 

Marking: The cables are marked "FIREX-HFFR".

Colours: Red, Yellow, Blue, Black, Green, Grey.

Packing: 90 mtrs. coils packed in protective cartons.

^ To Top